Applications
PV sanitary sampling valve is equipped with anti-rotation components and is more sanitary and reliable. It is mainly used for material sample collection in tanks and pipes. It can also be installed at the bottom of the tank or pipes for draining residual fluid.

PV sanitary sampling valve has two configurations.

PV-1 sanitary sampling valve adopts PTFE/EPDM seals and is operated by metal hand wheel. It is cost-effective and easy to operate.

PV-2 sanitary sampling valve adopts hard-metal seals and can be used for abrasive product sampling. It is operated by plastic hand wheel, and both angle and straight type structures are available.

Technical Data

Metal material Product wetted 316L (DIN-1.4404)
Non-product wetted 304 (DIN-1.4301) or PPS
We can provide EN 10204 3.1B certificate.
Seal material Standard PTFE/EPDM (PV-1), Metal seal (PV-2)
Options PTFE/Silicone, PTFE/FPM (PV-1), PTFE (PV-2)
All seal materials comply with FDA 177.2600.
Temperature Continuous working temperature -20°C ~ +135°C (EPDM)
Sterilization temperature 150°C (Max 20min)
Pressure Working pressure 0~10bar
Surface treatment Internal surface Ra≤0.8µm
External surface Shot blasting
Connection Connection methods: welding, thread, clamp