Selasa, 21 September 2010

Pressure Transducer

1. Gauge pressure transducer
The pressure of the measuring medium acts on the diaphragm. The bulging on the diaphragm, which increases with rising pressure, transmits via an amplifier a steady output signal in the form of a voltage or current.
2. Pressure differential pickup
From each of the two sides, different pressures act on a diaphragm. The higher of the two pressures causes the measuring diaphragm to bulge towards the side of the lower pressure. This generates via an amplifier a steady output signal in the form of a voltage or current.
3. Operating conditions
Perm. pressure see appliance rating plate
Perm. press. differential: see appliance rating plate
Perm. ambient temp.: 0 ... +70 °C
Perm. medium temp. at
the pressure connection: max. +70 °C
Perm. transport and
storage temperature: -60 ... +70 °C
Perm. ambient humidity: Class D
Perm. power supply DC 13-30V
Max. power consumption
(DIN 40040): 30 mA
Type of encl. (DIN 40050): IP 65